Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 304
Filtrar
2.
Biosens Bioelectron ; 258: 116298, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38701537

RESUMEN

Wireless activation of the enteric nervous system (ENS) in freely moving animals with implantable optogenetic devices offers a unique and exciting opportunity to selectively control gastrointestinal (GI) transit in vivo, including the gut-brain axis. Programmed delivery of light to targeted locations in the GI-tract, however, poses many challenges not encountered within the central nervous system (CNS). We report here the development of a fully implantable, battery-free wireless device specifically designed for optogenetic control of the GI-tract, capable of generating sufficient light over large areas to robustly activate the ENS, potently inducing colonic motility ex vivo and increased propulsion in vivo. Use in in vivo studies reveals unique stimulation patterns that increase expulsion of colonic content, likely mediated in part by activation of an extrinsic brain-gut motor pathway, via pelvic nerves. This technology overcomes major limitations of conventional wireless optogenetic hardware designed for the CNS, providing targeted control of specific neurochemical classes of neurons in the ENS and brain-gut axis, for direct modulation of GI-transit and associated behaviours in freely moving animals.

3.
Sci Adv ; 10(16): eadj0268, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38640247

RESUMEN

Continuous monitoring of biomarkers at locations adjacent to targeted internal organs can provide actionable information about postoperative status beyond conventional diagnostic methods. As an example, changes in pH in the intra-abdominal space after gastric surgeries can serve as direct indicators of potentially life-threatening leakage events, in contrast to symptomatic reactions that may delay treatment. Here, we report a bioresorbable, wireless, passive sensor that addresses this clinical need, designed to locally monitor pH for early detection of gastric leakage. A pH-responsive hydrogel serves as a transducer that couples to a mechanically optimized inductor-capacitor circuit for wireless readout. This platform enables real-time monitoring of pH with fast response time (within 1 hour) over a clinically relevant period (up to 7 days) and timely detection of simulated gastric leaks in animal models. These concepts have broad potential applications for temporary sensing of relevant biomarkers during critical risk periods following diverse types of surgeries.


Asunto(s)
Implantes Absorbibles , Transductores , Animales , Tecnología Inalámbrica , Concentración de Iones de Hidrógeno , Biomarcadores
5.
Proc Natl Acad Sci U S A ; 121(14): e2400868121, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38547066

RESUMEN

Partial cystectomy procedures for urinary bladder-related dysfunction involve long recovery periods, during which urodynamic studies (UDS) intermittently assess lower urinary tract function. However, UDS are not patient-friendly, they exhibit user-to-user variability, and they amount to snapshots in time, limiting the ability to collect continuous, longitudinal data. These procedures also pose the risk of catheter-associated urinary tract infections, which can progress to ascending pyelonephritis due to prolonged lower tract manipulation in high-risk patients. Here, we introduce a fully bladder-implantable platform that allows for continuous, real-time measurements of changes in mechanical strain associated with bladder filling and emptying via wireless telemetry, including a wireless bioresorbable strain gauge validated in a benchtop partial cystectomy model. We demonstrate that this system can reproducibly measure real-time changes in a rodent model up to 30 d postimplantation with minimal foreign body response. Studies in a nonhuman primate partial cystectomy model demonstrate concordance of pressure measurements up to 8 wk compared with traditional UDS. These results suggest that our system can be used as a suitable alternative to UDS for long-term postoperative bladder recovery monitoring.


Asunto(s)
Vejiga Urinaria , Infecciones Urinarias , Animales , Humanos , Vejiga Urinaria/cirugía , Urodinámica/fisiología , Prótesis e Implantes , Cistectomía
6.
Nat Biomed Eng ; 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38499643

RESUMEN

Diagnosing and monitoring inflammatory bowel diseases, such as Crohn's disease, involves the use of endoscopic imaging, biopsies and serology. These infrequent tests cannot, however, identify sudden onsets and severe flare-ups to facilitate early intervention. Hence, about 70% of patients with Crohn's disease require surgical intestinal resections in their lifetime. Here we report wireless, miniaturized and implantable temperature sensors for the real-time chronic monitoring of disease progression, which we tested for nearly 4 months in a mouse model of Crohn's-disease-like ileitis. Local measurements of intestinal temperature via intraperitoneally implanted sensors held in place against abdominal muscular tissue via two sutures showed the development of ultradian rhythms at approximately 5 weeks before the visual emergence of inflammatory skip lesions. The ultradian rhythms showed correlations with variations in the concentrations of stress hormones and inflammatory cytokines in blood. Decreasing average temperatures over the span of approximately 23 weeks were accompanied by an increasing percentage of inflammatory species in ileal lesions. These miniaturized temperature sensors may aid the early treatment of inflammatory bowel diseases upon the detection of episodic flare-ups.

7.
Science ; 383(6687): 1096-1103, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38452063

RESUMEN

Monitoring homeostasis is an essential aspect of obtaining pathophysiological insights for treating patients. Accurate, timely assessments of homeostatic dysregulation in deep tissues typically require expensive imaging techniques or invasive biopsies. We introduce a bioresorbable shape-adaptive materials structure that enables real-time monitoring of deep-tissue homeostasis using conventional ultrasound instruments. Collections of small bioresorbable metal disks distributed within thin, pH-responsive hydrogels, deployed by surgical implantation or syringe injection, allow ultrasound-based measurements of spatiotemporal changes in pH for early assessments of anastomotic leaks after gastrointestinal surgeries, and their bioresorption after a recovery period eliminates the need for surgical extraction. Demonstrations in small and large animal models illustrate capabilities in monitoring leakage from the small intestine, the stomach, and the pancreas.


Asunto(s)
Implantes Absorbibles , Fuga Anastomótica , Tracto Gastrointestinal , Ultrasonido , Animales , Humanos , Homeostasis , Estómago , Tracto Gastrointestinal/cirugía , Fuga Anastomótica/diagnóstico por imagen , Modelos Animales
8.
Biosens Bioelectron ; 253: 116166, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38428069

RESUMEN

Eccrine sweat can serve as a source of biomarkers for assessing physiological health and nutritional balance, for tracking loss of essential species from the body and for evaluating exposure to hazardous substances. The growing interest in this relatively underexplored class of biofluid arises in part from its non-invasive ability for capture and analysis. The simplest devices, and the only ones that are commercially available, exploit soft microfluidic constructs and colorimetric assays with purely passive modes of operation. The most sophisticated platforms exploit batteries, electronic components and radio hardware for inducing sweat, for electrochemical evaluation of its content and for wireless transmission of this information. The work reported here introduces a technology that combines the advantages of these two different approaches, in the form of a cost-effective, easy-to-use device that supports on-demand evaluation of multiple biomarkers in sweat. This flexible, skin-interfaced, miniaturized system incorporates a hydrogel that contains an approved drug to activate eccrine sweat glands, electrodes and a simple circuit and battery to delivery this drug by iontophoresis through the surface of the skin, microfluidic channels and microreservoirs to capture the induced sweat, and multiple colorimetric assays to evaluate the concentrations of chloride, zinc, and iron. As demonstrated in healthy human participants monitored before and after a meal, such devices yield results that match those of traditional laboratory analysis techniques. Clinical studies that involve cystic fibrosis pediatric patients illustrate the use of this technology as a simple, painless, and reliable alternative to traditional hospital systems for measurements of sweat chloride.


Asunto(s)
Técnicas Biosensibles , Sudor , Humanos , Niño , Cloruros , Colorimetría , Biomarcadores
9.
Adv Mater ; 36(15): e2307782, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38303684

RESUMEN

Bio/ecoresorbable electronic systems create unique opportunities in implantable medical devices that serve a need over a finite time period and then disappear naturally to eliminate the need for extraction surgeries. A critical challenge in the development of this type of technology is in materials that can serve as thin, stable barriers to surrounding ground water or biofluids, yet ultimately dissolve completely to benign end products. This paper describes a class of inorganic material (silicon oxynitride, SiON) that can be formed in thin films by plasma-enhanced chemical vapor deposition for this purpose. In vitro studies suggest that SiON and its dissolution products are biocompatible, indicating the potential for its use in implantable devices. A facile process to fabricate flexible, wafer-scale multilayer films bypasses limitations associated with the mechanical fragility of inorganic thin films. Systematic computational, analytical, and experimental studies highlight the essential materials aspects. Demonstrations in wireless light-emitting diodes both in vitro and in vivo illustrate the practical use of these materials strategies. The ability to select degradation rates and water permeability through fine tuning of chemical compositions and thicknesses provides the opportunity to obtain a range of functional lifetimes to meet different application requirements.


Asunto(s)
Implantes Absorbibles , Electrónica , Agua/química
10.
Adv Mater ; 36(19): e2309421, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38339983

RESUMEN

Bioresorbable electronic devices as temporary biomedical implants represent an emerging class of technology relevant to a range of patient conditions currently addressed with technologies that require surgical explantation after a desired period of use. Obtaining reliable performance and favorable degradation behavior demands materials that can serve as biofluid barriers in encapsulating structures that avoid premature degradation of active electronic components. Here, this work presents a materials design that addresses this need, with properties in water impermeability, mechanical flexibility, and processability that are superior to alternatives. The approach uses multilayer assemblies of alternating films of polyanhydride and silicon oxynitride formed by spin-coating and plasma-enhanced chemical vapor deposition , respectively. Experimental and theoretical studies investigate the effects of material composition and multilayer structure on water barrier performance, water distribution, and degradation behavior. Demonstrations with inductor-capacitor circuits, wireless power transfer systems, and wireless optoelectronic devices illustrate the performance of this materials system as a bioresorbable encapsulating structure.


Asunto(s)
Electrónica , Implantes Absorbibles , Agua/química , Tecnología Inalámbrica , Materiales Biocompatibles/química
11.
Small ; : e2309112, 2023 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-38150610

RESUMEN

A sulfur vacancy-rich, Sn-doped as well as carbon-coated MoS2 composite (Vs-SMS@C) is rationally synthesized via a simple hydrothermal method combined with ball-milling reduction, which enhances the sodium storage performance. Benefiting from the 3D fast Na+ transport network composed of the defective carbon coating, Mo─S─C bonds, enlarged interlayer spacing, S-vacancies, and lattice distortion in the composite, the Na+ storage kinetics is significantly accelerated. As expected, Vs-SMS@C releases an ultrahigh reversible capacity of 1089 mAh g-1 at 0.1 A g-1 , higher than the theoretical capacity. It delivers a satisfactory capacity of 463 mAh g-1 at a high current density of 10 A g-1 , which is the state-of-the-art rate capability compared to other MoS2 based sodium ion battery anodes to the knowledge. Moreover, a super long-term cycle stability is achieved by Vs-SMS@C, which keeps 91.6% of the initial capacity after 3000 cycles under the current density of 5 A g-1 in the voltage of 0.3-3.0 V. The sodium storage mechanism of Vs-SMS@C is investigated by employing electrochemical methods and ex situ techniques. The synergistic effect between S-vacancies and doped-Sn is evidenced by DFT calculations. This work opens new ideas for seeking excellent metal sulfide anodes.

12.
Ann Gastroenterol Surg ; 7(5): 772-783, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37663961

RESUMEN

Background: Laparoscopic common bile duct exploration with primary closure (LCBDE-PC) exhibits more benefits than other surgeries for patients with choledocholithiasis. It remains unclear whether it is feasible for and beneficial to elderly individuals. This study aimed to clarify and stratify elderly patients who would benefit from LCBDE-PC. Methods: A retrospective study of 1240 patients with choledocholithiasis who underwent laparoscopic procedures between 2011 and 2019 was conducted. Patients were divided into the young group (<65 years old, n = 708) and the elderly group (≥65 years old, n = 532). Perioperative outcomes were compared between the two groups. Results: Laparoscopic common bile duct exploration with primary closure was successfully performed in 90.20% of the elderly and 94.20% of the young. No significant differences were observed between the two groups regarding reoperation, postoperative bile leakage, residual stones, drainage removal, and postoperative mortality. Compared with the young, the elderly had longer postoperative hospital stay (p = 0.035) and delayed postoperative eating time (p = 0.036) in the matched cohort. Independent risk factors for failed LCBDE-PC were preoperative pancreatitis (p = 0.018), year of the surgeon's experience (p = 0.008), preoperative C-reactive protein level (p = 0.034), preoperative total bilirubin (p = 0.021), impacted common bile duct (CBD) stones (p = 0.006), blood loss (p = 0.001), and edema of the CBD (p = 0.001). A novel nomogram for predicting failed LCBDE-PC in elderly individuals exhibited a sufficient discriminative ability according to the estimated area under the curve (AUC) of 0.869 (95% CI: 0.817-0.921, p < 0.01). Conclusion: Laparoscopic common bile duct exploration with primary closure is safe, feasible, and effective for elderly individuals with choledocholithiasis. Elderly patients with a high risk of failed LCBDE-PC should be cautious of undergoing LCBDE-PC.

13.
Mol Clin Oncol ; 19(4): 77, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37719039

RESUMEN

Wnt/ß-catenin signaling is associated with epithelial-mesenchymal transformation (EMT), which serves an important role in hepatocellular carcinoma (HCC) invasion and metastasis. Frankincense and myrrh (FM) are antitumor agents commonly used in clinical practice. The present study aimed to investigate the effect and mechanism of water extract of FM on the progression of liver cancer cells. FM was applied to study its effects on HCC cell proliferation. Cell migration and invasion were evaluated by wound healing and Transwell assays. In addition, western blot was used to study the protein levels associated with EMT and Wnt/ß-catenin signaling. The nuclear translocation of ß-catenin was detected by immunofluorescence assay. A non-toxic dose of FM significantly inhibited invasion and metastasis of liver cancer cells. Furthermore, FM promoted expression of EMT marker E-cadherin, while decreasing expression of vimentin and N-cadherin. Finally, the protein and the nuclear staining levels of Disheveled 2 and ß-catenin were both suppressed by water extract of FM. The water extract of FM inhibited the migration and invasion of liver cancer cells and inhibited EMT by suppressing activation of the Wnt/ß-catenin signaling pathway.

14.
Science ; 381(6662): 1105-1112, 2023 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-37676965

RESUMEN

Early-stage organ transplant rejection can be difficult to detect. Percutaneous biopsies occur infrequently and are risky, and measuring biomarker levels in blood can lead to false-negative and -positive outcomes. We developed an implantable bioelectronic system capable of continuous, real-time, long-term monitoring of the local temperature and thermal conductivity of a kidney for detecting inflammatory processes associated with graft rejection, as demonstrated in rat models. The system detects ultradian rhythms, disruption of the circadian cycle, and/or a rise in kidney temperature. These provide warning signs of acute kidney transplant rejection that precede changes in blood serum creatinine/urea nitrogen by 2 to 3 weeks and approximately 3 days for cases of discontinued and absent administration of immunosuppressive therapy, respectively.


Asunto(s)
Diagnóstico Precoz , Rechazo de Injerto , Enfermedades Renales , Trasplante de Riñón , Complicaciones Posoperatorias , Tecnología Inalámbrica , Animales , Ratas , Riñón , Rechazo de Injerto/diagnóstico , Tecnología Inalámbrica/instrumentación , Monitoreo Fisiológico/instrumentación
15.
Small ; 19(49): e2305017, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37528504

RESUMEN

Eco/bioresorbable electronics represent an emerging class of technology defined by an ability to dissolve or otherwise harmlessly disappear in environmental or biological surroundings after a period of stable operation. The resulting devices provide unique capabilities as temporary biomedical implants, environmental sensors, and related systems. Recent publications report schemes to overcome challenges in fabrication that follow from the low thermostability and/or high chemical reactivity of the eco/bioresorbable constituent materials. Here, this work reports the use of high-speed sewing machines, as the basis for a high-throughput manufacturing technique that addresses many requirements for these applications, without the need for high temperatures or reactive solvents. Results demonstrate that a range of eco/bioresorbable metal wires and polymer threads can be embroidered into complex, user-defined conductive patterns on eco/bioresorbable substrates. Functional electronic components, such as stretchable interconnects and antennas are possible, along with fully integrated systems. Examples of the latter include wirelessly powered light-emitting diodes, radiofrequency identification tags, and temporary cardiac pacemakers. These advances add to a growing range of options in high-throughput, automated fabrication of eco/bioresorbable electronics.


Asunto(s)
Implantes Absorbibles , Electrónica , Metales , Polímeros , Solventes
16.
Mater Horiz ; 10(11): 4992-5003, 2023 10 30.
Artículo en Inglés | MEDLINE | ID: mdl-37641877

RESUMEN

Systems for capture, storage and analysis of eccrine sweat can provide insights into physiological health status, quantify losses of water, electrolytes, amino acids and/or other essential species, and identify exposures to adverse environmental species or illicit drugs. Recent advances in materials and device designs serve as the basis for skin-compatible classes of microfluidic platforms and in situ colorimetric assays for precise assessments of sweat rate, sweat loss and concentrations of wide-ranging types of biomarkers in sweat. This paper presents a set of findings that enhances the performance of these systems through the use of microfluidic networks, integrated valves and microscale optical cuvettes formed by three dimensional printing in hard/soft hybrid materials systems, for accurate spectroscopic and fluorometric assays. Field studies demonstrate the capability of these microcuvette systems to evaluate the concentrations of copper, chloride, and glucose in sweat, along with the pH of sweat, with laboratory-grade accuracy and sensitivity.


Asunto(s)
Microfluídica , Sudor , Sudor/química , Sudor/metabolismo , Microfluídica/métodos , Dispositivos Laboratorio en un Chip , Epidermis , Piel/química , Piel/metabolismo
17.
Adv Sci (Weinh) ; 10(27): e2303429, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37518771

RESUMEN

Myocardial infarction (MI) is one of the leading causes of death and disability. Recently developed cardiac patches provide mechanical support and additional conductive paths to promote electrical signal propagation in the MI area to synchronize cardiac excitation and contraction. Cardiac patches based on conductive polymers offer attractive features; however, the modest levels of elasticity and high impedance interfaces limit their mechanical and electrical performance. These structures also operate as permanent implants, even in cases where their utility is limited to the healing period of tissue damaged by the MI. The work presented here introduces a highly conductive cardiac patch that combines bioresorbable metals and polymers together in a hybrid material structure configured in a thin serpentine geometry that yields elastic mechanical properties. Finite element analysis guides optimized choices of layouts in these systems. Regular and synchronous contraction of human induced pluripotent stem cell-derived cardiomyocytes on the cardiac patch and ex vivo studies offer insights into the essential properties and the bio-interface. These results provide additional options in the design of cardiac patches to treat MI and other cardiac disorders.


Asunto(s)
Células Madre Pluripotentes Inducidas , Infarto del Miocardio , Humanos , Implantes Absorbibles , Miocitos Cardíacos , Polímeros/química , Tecnología
18.
Adv Sci (Weinh) ; : e2301232, 2023 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-37357139

RESUMEN

Magnetic resonance imaging (MRI) is widely used in clinical care and medical research. The signal-to-noise ratio (SNR) in the measurement affects parameters that determine the diagnostic value of the image, such as the spatial resolution, contrast, and scan time. Surgically implanted radiofrequency coils can increase SNR of subsequent MRI studies of adjacent tissues. The resulting benefits in SNR are, however, balanced by significant risks associated with surgically removing these coils or with leaving them in place permanently. As an alternative, here the authors report classes of implantable inductor-capacitor circuits made entirely of bioresorbable organic and inorganic materials. Engineering choices for the designs of an inductor and a capacitor provide the ability to select the resonant frequency of the devices to meet MRI specifications (e.g., 200 MHz at 4.7 T MRI). Such devices enhance the SNR and improve the associated imaging capabilities. These simple, small bioelectronic systems function over clinically relevant time frames (up to 1 month) at physiological conditions and then disappear completely by natural mechanisms of bioresorption, thereby eliminating the need for surgical extraction. Imaging demonstrations in a nerve phantom and a human cadaver suggest that this technology has broad potential for post-surgical monitoring/evaluation of recovery processes.

19.
Nat Biomed Eng ; 7(10): 1252-1269, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37106153

RESUMEN

Fully implantable wireless systems for the recording and modulation of neural circuits that do not require physical tethers or batteries allow for studies that demand the use of unconstrained and freely behaving animals in isolation or in social groups. Moreover, feedback-control algorithms that can be executed within such devices without the need for remote computing eliminate virtual tethers and any associated latencies. Here we report a wireless and battery-less technology of this type, implanted subdermally along the back of freely moving small animals, for the autonomous recording of electroencephalograms, electromyograms and body temperature, and for closed-loop neuromodulation via optogenetics and pharmacology. The device incorporates a system-on-a-chip with Bluetooth Low Energy for data transmission and a compressed deep-learning module for autonomous operation, that offers neurorecording capabilities matching those of gold-standard wired systems. We also show the use of the implant in studies of sleep-wake regulation and for the programmable closed-loop pharmacological suppression of epileptic seizures via feedback from electroencephalography. The technology can support a broader range of applications in neuroscience and in biomedical research with small animals.

20.
Nat Biomed Eng ; 7(10): 1215-1228, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37037964

RESUMEN

Devices for monitoring blood haemodynamics can guide the perioperative management of patients with cardiovascular disease. Current technologies for this purpose are constrained by wired connections to external electronics, and wireless alternatives are restricted to monitoring of either blood pressure or blood flow. Here we report the design aspects and performance parameters of an integrated wireless sensor capable of implantation in the heart or in a blood vessel for simultaneous measurements of pressure, flow rate and temperature in real time. The sensor is controlled via long-range communication through a subcutaneously implanted and wirelessly powered Bluetooth Low Energy system-on-a-chip. The device can be delivered via a minimally invasive transcatheter procedure or it can be mounted on a passive medical device such as a stent, as we show for the case of the pulmonary artery in a pig model and the aorta and left ventricle in a sheep model, where the device performs comparably to clinical tools for monitoring of blood flow and pressure. Battery-less and wireless devices such as these that integrate capabilities for flow, pressure and temperature sensing offer the potential for continuous monitoring of blood haemodynamics in patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...